Vertical-Tank Compressors
A1 offers vertical-tank piston compressors from Schulz and EL-AV, including Schulz receivers from 24 gallon to 80 gallon. Upright storage makes height part of the floor-space decision, but the complete package still needs room for cooling, draining and maintenance. The Schulz MCSV 20 AP AUDAZ places an 80-gallon vertical ASME tank in a package measuring 24 x 28 x 67 in. Start with the usable installation space, then choose air output, pressure and electrical supply for the work.
Compare Vertical-Tank Compressors
Specifications are the manufacturer's published figures for each model. Tap a model for full details, documents and a quote.
| Model | Brand | Horsepower | Air flow | Max pressure | Tank | Voltage | Phase | Noise | Price |
|---|---|---|---|---|---|---|---|---|---|
| Schulz MCSV 20 AP AUDAZ Vertical 5 HP Piston (1-Phase) | Schulz | 5 HP | 14.2 CFM | 175 PSI | 80 gallon ASME, vertical | 230V | Single-Phase | – | |
| Schulz MCSV 20 AP AUDAZ Vertical 5 HP Piston (3-Phase) | Schulz | 5 HP | 14.2 CFM | 175 PSI | 80 gallon ASME, vertical | 230V | Three-Phase | – | |
| Schulz 7580VV30X-3 7.5 HP 80-Gal Piston Air Compressor | Schulz | 7.5 HP | 20.1 CFM | 175 PSI | 80 gallon ASME, vertical | 230V / 460V | Three-Phase | – | |
| Schulz 360VL18X-1 3 HP 60-Gal Piston Air Compressor | Schulz | 3 HP | 13.8 CFM | 145 PSI | 60 gallon ASME, vertical | 220V | Single-Phase | – | |
| Schulz 224VL10X-1 2 HP 24-Gal Piston Air Compressor | Schulz | 2 HP | 5 CFM | 145 PSI | 24 gallon, vertical | 115V | Single-Phase | – | |
| EL-AV BL601080GVP3P Two-Stage Cast-Iron Vertical Piston Compressor (10 HP, 80-Gal, Three-Phase) | EL-AV | 10 HP | 36 CFM | 175 PSI | 80 US Gallon Vertical, ASME-coded | 208V / 230V | Three-Phase | 76 dB(A) | $7,134.75 |
| EL-AV BL30780GVP3P Two-Stage Cast-Iron Vertical Piston Compressor (7.5 HP, 80-Gal, Three-Phase) | EL-AV | 7.5 HP | 26 CFM | 175 PSI | 80 US Gallon Vertical, ASME-coded | 208V / 230V | Three-Phase | 73 dB(A) | $5,981.85 |
| EL-AV BL3060GVP3P Two-Stage Cast-Iron Vertical Piston Compressor (5 HP, 60-Gal, Three-Phase) | EL-AV | 5 HP | 18 CFM | 175 PSI | 60 US Gallon Vertical, ASME-coded | 208V / 230V | Three-Phase | 73 dB(A) | $5,008.50 |
| EL-AV BL601080GVP1P Two-Stage Cast-Iron Vertical Piston Compressor (10 HP, 80-Gal, Single-Phase) | EL-AV | 10 HP | 36 CFM | 175 PSI | 80 US Gallon Vertical, ASME-coded | 208V / 230V | Single-Phase | 76 dB(A) | $6,804.00 |
| EL-AV BL30780GVP1P Two-Stage Cast-Iron Vertical Piston Compressor (7.5 HP, 80-Gal, Single-Phase) | EL-AV | 7.5 HP | 26 CFM | 175 PSI | 80 US Gallon Vertical, ASME-coded | 208V / 230V | Single-Phase | 73 dB(A) | $5,651.10 |
| EL-AV BL3060GVP1P Two-Stage Cast-Iron Vertical Piston Compressor (5 HP, 60-Gal, Single-Phase) | EL-AV | 5 HP | 18 CFM | 175 PSI | 60 US Gallon Vertical, ASME-coded | 208V / 230V | Single-Phase | 73 dB(A) | $4,677.75 |
| Schulz 560VV20-1 5 HP 60-Gal Oil-Free Air Compressor | Schulz | 5 HP | 13.3 CFM | 120 PSI | 60 gallon | 230V | Single-Phase | – | |
| Schulz 360VV15-1 3 HP 60-Gal Oil-Free Air Compressor | Schulz | 3 HP | 6.6 CFM | 120 PSI | 60 gallon | 230V | Single-Phase | – |
Will a vertical tank save usable floor space?
A vertical receiver puts more vessel volume into height, which can help when floor area is tight. Check overhead space and the route into the building as well as the final position. A narrow vessel still needs space around the compressor, controls and drain for operation and maintenance.
The Schulz MCSV 20 AP AUDAZ single-phase vertical package measures 24 x 28 x 67 in with its 80-gallon ASME tank. The Schulz 224VL10X-1 measures 24 x 17 x 48 in with a 24-gallon vertical tank. These complete package dimensions give you a useful starting point for layout; leave the required working space beyond them.
How do I choose storage without confusing it with air output?
Choose receiver capacity around the duration and frequency of demand peaks. More storage can support a short burst, but the compressor must replenish that air between bursts and keep pace during longer runs. Set the required delivery from the equipment being used, then select the storage arrangement.
For example, the Schulz MCSV 20 AP AUDAZ single-phase version has 14.2 CFM, while EL-AV's BL601080GVP1P has 36 CFM, as listed by the manufacturer. Each uses a vertical receiver with an 80-gallon capacity. Sharing that storage volume does not establish equal output or the same package dimensions.
What pressure and electrical checks matter for an upright package?
The Schulz 224VL10X-1 uses 115V single-phase power and has a 145 PSI maximum. The single-phase MCSV 20 AP AUDAZ uses 230V with a 175 PSI maximum. Select from the work's pressure and delivery requirements, then have the circuit assessed for the chosen motor.
EL-AV's BL601080GVP1P provides another single-phase arrangement with 208V / 230V choices and a 175 PSI maximum. Decide the intended voltage before installation planning. Send us the available space, electrical supply and air demand for help choosing the vertical receiver package around the actual job.
Where length is available but height is not, compare horizontal tank compressors. To shop by storage, see 60 gallon and 80 gallon air compressors, or browse all piston air compressors.
Vertical-Tank Compressors: common questions
What dimensions should I use to plan an upright compressor space?
Use the complete package dimensions and allow the required cooling and maintenance access beyond them. Schulz's single-phase MCSV 20 AP AUDAZ vertical package measures 24 x 28 x 67 in with an 80-gallon ASME tank. Check overhead space and the delivery access route as part of the layout.
Does an 80-gallon vertical tank establish the compressor's airflow?
The single-phase Schulz MCSV 20 AP AUDAZ has 14.2 CFM, while the EL-AV BL601080GVP1P has 36 CFM. Each carries an 80-gallon vertical receiver. Storage capacity therefore leaves airflow as a separate selection based on the air consumed during the work cycle.
Is there a vertical receiver package powered by 115V?
The Schulz 224VL10X-1 uses 115V single-phase power and has a 24-gallon vertical tank. Its maximum pressure is 145 PSI. Check the air required by the work as well as the circuit requirements, since the supply voltage does not establish usable air capacity.
What needs access around the bottom of a vertical receiver?
Allow practical access for condensate draining, inspection and maintenance around the receiver base. An upright vessel can conserve floor area, but a location that blocks the drain creates a maintenance problem. Include the drain route and working access when measuring the installation space.