Enclosed / Sound-Attenuated Compressors
A1 offers enclosed Anest Iwata oil-less scroll compressors alongside Schulz rotary screw packages. Choose the package around the sound rating, receiver arrangement and room needed for cooling and service. Anest Iwata's SLTE-3 brings a sound enclosure and horizontal 30-gallon receiver together; the larger SLTE-20D carries a horizontal 120-gallon duplex receiver. An enclosure does not choose capacity or electrical supply for you. Keep those decisions tied to the air load and the location where the compressor will operate.
Compare Enclosed / Sound-Attenuated Compressors
Specifications are the manufacturer's published figures for each model. Tap a model for full details, documents and a quote.
| Model | Brand | Horsepower | Air flow | Max pressure | Tank | Voltage | Phase | Noise | Price |
|---|---|---|---|---|---|---|---|---|---|
| Schulz SRP 4250E Flex 250 HP Rotary Screw Air Compressor | Schulz | 250 HP | 285–1,141 CFM @ 125 PSI | 125 PSI (8.6 bar) | Base mounted (no tank) | 460V | Three-Phase | 83 dB(A) | |
| Schulz SRP 4200E Flex 200 HP Rotary Screw Air Compressor | Schulz | 200 HP | 165–855 CFM @ 125 PSI | 125 PSI (8.6 bar) | Base mounted (no tank) | 460V | Three-Phase | 81 dB(A) | |
| Schulz SRP 4150E Flex 150 HP Rotary Screw Air Compressor | Schulz | 150 HP | 177–670 CFM @ 125 PSI | 125 PSI (8.6 bar) | Base mounted (no tank) | 460V | Three-Phase | 81 dB(A) | |
| Schulz SRP 4125E Flex 125 HP Rotary Screw Air Compressor | Schulz | 125 HP | 117–500 CFM @ 125 PSI | 125 PSI (8.6 bar) | Base mounted (no tank) | 460V | Three-Phase | 79 dB(A) | |
| Schulz SRP 4100E Flex 100 HP Rotary Screw Air Compressor | Schulz | 100 HP | 133–385 CFM @ 125 PSI | 125 PSI (8.6 bar) | Base mounted (no tank) | 460V | Three-Phase | 79 dB(A) | |
| Schulz SRP 4050E Flex 50 HP Rotary Screw Air Compressor | Schulz | 50 HP | 48–207 CFM @ 125 PSI | 125 PSI (8.6 bar) | Base mounted (no tank) | 230V / 460V | Three-Phase | 71 dB(A) | |
| Schulz SRP 4075E Flex 75 HP Rotary Screw Air Compressor | Schulz | 75 HP | 77–305 CFM @ 125 PSI | 125 PSI (8.6 bar) | Base mounted (no tank) | 460V | Three-Phase | 78 dB(A) | |
| Anest Iwata SLTE-2 Oil-Less Scroll Compressor (Enclosed) | Anest Iwata | 2 HP | 5.4 CFM | 115 PSI | 30 gallon horizontal, sound enclosure | 230V | Single-Phase | 50 dB(A) | $13,300.00 |
| Schulz SRP 4050E Dynamic 50 HP Rotary Screw Air Compressor | Schulz | 50 HP | 207 CFM | 125 PSI (8.6 bar) | Base mounted (no tank) | 230V / 460V | Three-Phase | 76 dB(A) | |
| Schulz SRP 4040E Dynamic 40 HP Rotary Screw Air Compressor | Schulz | 40 HP | 150 CFM | 125 PSI (8.6 bar) | 120 gallon ASME, horizontal | 230V / 460V | Three-Phase | 76 dB(A) | |
| Schulz SRP 4030E Dynamic 30 HP Rotary Screw Air Compressor | Schulz | 30 HP | 117 CFM | 125 PSI (8.6 bar) | 120 gallon ASME, horizontal | 230V / 460V | Three-Phase | 70 dB(A) | |
| Schulz SRP 4025E Dynamic 25 HP Rotary Screw Air Compressor | Schulz | 25 HP | 92 CFM | 125 PSI (8.6 bar) | 120 gallon ASME, horizontal | 230V / 460V | Three-Phase | 69 dB(A) | |
| Schulz SRP 4020E Dynamic 20 HP Rotary Screw Air Compressor | Schulz | 20 HP | 74 CFM | 125 PSI (8.6 bar) | 120 gallon ASME, horizontal | 230V / 460V | Three-Phase | 68 dB(A) | |
| Schulz SRP 4015 Dynamic 15 HP Rotary Screw Air Compressor | Schulz | 15 HP | 51 CFM | 125 PSI (8.6 bar) | 120 gallon ASME, horizontal | 230V / 460V | Three-Phase | 69 dB(A) | |
| Schulz SRP 4010 Dynamic 10 HP Rotary Screw Air Compressor | Schulz | 10 HP | 35 CFM | 125 PSI (8.6 bar) | 120 gallon ASME, horizontal | 230V / 460V | Three-Phase | 69 dB(A) | |
| Schulz SRP 4008 Dynamic 7.5 HP Rotary Screw Air Compressor | Schulz | 7.5 HP | 25 CFM | 125 PSI (8.6 bar) | 60 gallon ASME, horizontal | 230V / 460V | Single-Phase / Three-Phase | 69 dB(A) | |
| Anest Iwata SLE-60 Oil-Less Scroll Compressor (Modular Industrial Enclosed) | Anest Iwata | 60 HP | 172.5 CFM | 115 PSI | Base-mount (no tank) | 460V | Three-Phase | 63 dB(A) | $123,500.00 |
| Anest Iwata SLE-50 Oil-Less Scroll Compressor (Modular Industrial Enclosed) | Anest Iwata | 50 HP | 143.7 CFM | 115 PSI | Base-mount (no tank) | 460V | Three-Phase | 62 dB(A) | $109,250.00 |
| Anest Iwata SLE-40 Oil-Less Scroll Compressor (Modular Industrial Enclosed) | Anest Iwata | 40 HP | 118.4 CFM | 115 PSI | Base-mount (no tank) | 230V / 460V | Three-Phase | 60 dB(A) | $90,250.00 |
| Anest Iwata SLE-20 Oil-Less Scroll Compressor (Modular Industrial Enclosed) | Anest Iwata | 20 HP | 59.2 CFM | 115 PSI | Base-mount (no tank) | 230V / 460V | Three-Phase | 58 dB(A) | $52,250.00 |
| Anest Iwata SLE-30 Oil-Less Scroll Compressor (Modular Industrial Enclosed) | Anest Iwata | 30 HP | 88.8 CFM | 115 PSI | Base-mount (no tank) | 230V / 460V | Three-Phase | 59 dB(A) | $71,250.00 |
| Anest Iwata SLE-15 Oil-Less Scroll Compressor (Modular Industrial Enclosed) | Anest Iwata | 15 HP | 44.4 CFM | 115 PSI | Base-mount (no tank) | 230V / 460V | Three-Phase | 56 dB(A) | $39,900.00 |
| Anest Iwata SLE-10 Oil-Less Scroll Compressor (Modular Industrial Enclosed) | Anest Iwata | 10 HP | 29.6 CFM | 115 PSI | Base-mount (no tank) | 230V / 460V | Three-Phase | 53 dB(A) | $30,400.00 |
| Anest Iwata SLE-5 Oil-Less Scroll Compressor (Industrial Enclosed) | Anest Iwata | 5 HP | 14.8 CFM | 115 PSI | Base-mount (no tank) | 230V / 460V | Three-Phase | 50 dB(A) | $13,490.00 |
| Anest Iwata SLE-3 Oil-Less Scroll Compressor (Industrial Enclosed) | Anest Iwata | 3 HP | 7.8 CFM | 115 PSI | Base-mount (no tank) | 230V / 460V | Single-Phase / Three-Phase | 50 dB(A) | $11,875.00 |
| Anest Iwata SLE-2 Oil-Less Scroll Compressor (Industrial Enclosed) | Anest Iwata | 2 HP | 5.4 CFM | 115 PSI | Base-mount (no tank) | 230V | Single-Phase | 46 dB(A) | $11,400.00 |
| Anest Iwata SLTE-10D Oil-Less Scroll Compressor (Duplex Enclosed) | Anest Iwata | 10 HP | 29.6 CFM | 115 PSI | 120 gallon horizontal (duplex), sound enclosure | 230V / 460V | Three-Phase | 62 dB(A) | $28,500.00 |
| Anest Iwata SLTE-7.5 Oil-Less Scroll Compressor (Enclosed) | Anest Iwata | 7.5 HP | 22.6 CFM | 115 PSI | 80 gallon horizontal, sound enclosure | 230V / 460V | Three-Phase | 64 dB(A) | $22,040.00 |
| Anest Iwata SLTE-5 Oil-Less Scroll Compressor (Enclosed) | Anest Iwata | 5 HP | 14.8 CFM | 115 PSI | 60 gallon horizontal, sound enclosure | 230V / 460V | Three-Phase | 61 dB(A) | $15,200.00 |
| Anest Iwata SLTE-3 Oil-Less Scroll Compressor (Enclosed) | Anest Iwata | 3 HP | 7.8 CFM | 115 PSI | 30 gallon horizontal, sound enclosure | 230V / 460V | Single-Phase / Three-Phase | 56 dB(A) | $13,490.00 |
What does a sound enclosure change when I choose a location?
A sound enclosure puts acoustic treatment around the compressor, but the finished package's noise rating is the useful figure for location planning. Anest Iwata's SLTE-3 combines a sound enclosure with a 56 dB(A) rating, as listed by the manufacturer. Use that package rating when considering a position near occupied work areas.
Sound treatment does not remove heat or the need for maintenance access. Leave the cooling air path open and provide room to reach routine service points. Closing a machine into a tight room can create an installation problem even when the acoustic package is attractive for the people working nearby.
Should storage sit beneath the enclosure or elsewhere?
The SLTE-20D places a sound enclosure with a horizontal 120-gallon duplex receiver and 59.4 CFM output. That arrangement keeps air storage in the compressor package, so draining and reaching the receiver become part of its floor-space requirement. Choose the whole package location rather than measuring the cabinet alone.
Anest Iwata's enclosed SLE-15 takes a different approach: it is base mounted without a tank. Receiver capacity and position can then be decided as part of the air system layout. If storage needs to stand elsewhere, that separation can matter more to the floor plan than choosing a receiver package by motor size.
How do I keep acoustic selection separate from capacity?
First establish the air required while production is running. Among the Schulz screw choices, the SRP 4100E Flex supplies 133–385 CFM @ 125 PSI and uses 460V three-phase power. Those requirements define a plant installation decision, with the circuit and air system planned around the selected machine.
Then address noise and access at the intended position. The Anest Iwata SLBE, for example, is base mounted with a sound enclosure and a 53 dB(A) rating. A cabinet description alone cannot establish airflow, receiver capacity or electrical requirements, so keep each requirement in the specification when you request a quote.
Enclosed scroll packages also appear under scroll compressors and oil-free compressors. For a quiet screw package, compare the rotary screw range; this article on Anest Iwata scroll compressors covers what the enclosed models are built for.
Enclosed / Sound-Attenuated Compressors: common questions
Does an acoustic enclosure let me restrict cooling airflow?
Cooling and service access still need room around an enclosed compressor. Acoustic treatment addresses sound, while the compressor continues to reject heat. Choose its position with the cooling air path and access panels in mind, then use the package's noise rating when assessing nearby occupied areas.
What receiver arrangement comes with the enclosed SLTE-20D?
Anest Iwata's SLTE-20D combines a sound enclosure, 59.4 CFM output and a horizontal 120-gallon duplex receiver. That keeps storage with the compressor. Its location needs access for draining and maintenance as well as space for the cabinet, rather than a floor plan based only on enclosure size.
Can a base-mounted compressor still have a sound enclosure?
The Anest Iwata SLBE is base mounted with a sound enclosure and a 53 dB(A) rating. For the SLBE's electrical connection, select the required motor configuration from 208V / 230V / 460V three-phase choices. Base mounting describes the package arrangement; select the motor supply and receiver plan as separate parts of the installation.
Should I choose the acoustic package before measuring production demand?
Establish demand first, then evaluate noise at the proposed location. The Schulz SRP 4100E Flex has a 133–385 CFM @ 125 PSI operating range and requires 460V three-phase power. Allow room for access panels and cooling air as well as the circuit and receiver layout.