{"title":"Brazed-Plate Heat Exchanger Dryers","description":"Refrigerated dryers featuring brazed-plate heat exchangers.","products":[{"product_id":"el-av-elrd40-u-refrigerated-air-dryer","title":"EL-AV ELRD40-U Refrigerated Compressed Air Dryer (40 CFM, 1\/2\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD40-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 CFM \/ 1,130 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526528761937,"sku":"ELRD40-U","price":2050.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/EL-AV_ELRD_Air_Dryers_ELRD40-U_094ab2c6-294e-4b57-ad72-70a01801fb06.webp?v=1780539423"},{"product_id":"el-av-elrd60-u-refrigerated-air-dryer","title":"EL-AV ELRD60-U Refrigerated Compressed Air Dryer (60 CFM, 1\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD60-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 CFM \/ 1,700 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526528860241,"sku":"ELRD60-U","price":2190.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/EL-AV_ELRD_Air_Dryers_ELRD40-U_f9ecea8b-3a98-49c0-af4a-8c60038328f5.webp?v=1780539426"},{"product_id":"el-av-elrd80-u-refrigerated-air-dryer","title":"EL-AV ELRD80-U Refrigerated Compressed Air Dryer (80 CFM, 1\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD80-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 CFM \/ 2,260 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526528925777,"sku":"ELRD80-U","price":2550.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/EL-AV_ELRD_Air_Dryers_ELRD40-U_d8b36f25-b8af-4a1b-a6f4-cdc24a1aefaf.webp?v=1780539430"},{"product_id":"el-av-elrd100-u-refrigerated-air-dryer","title":"EL-AV ELRD100-U Refrigerated Compressed Air Dryer (100 CFM, 1\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD100-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 CFM \/ 2,830 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526528958545,"sku":"ELRD100-U","price":2980.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/EL-AV_ELRD_Air_Dryers_ELRD40-U_2ff72d98-ea76-4499-b39d-a995c37b4b82.webp?v=1780539436"},{"product_id":"el-av-elrd150-u-refrigerated-air-dryer","title":"EL-AV ELRD150-U Refrigerated Compressed Air Dryer (150 CFM, 1 1\/4\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD150-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 CFM \/ 4,250 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526529024081,"sku":"ELRD150-U","price":4190.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/EL-AV_ELRD_Air_Dryers_ELRD40-U_6f5af1c6-b11e-45bc-9ed1-27b2eb756c03.webp?v=1780539440"},{"product_id":"el-av-elrd300-u-refrigerated-air-dryer","title":"EL-AV ELRD300-U Refrigerated Compressed Air Dryer (300 CFM, 2\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD300-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 CFM \/ 8,500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526529089617,"sku":"ELRD300-U","price":6950.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/SD_dryers_Small__20240326141348.614_78cf5545-f947-4ae4-95a4-7c0371766ce0.png?v=1781016155"},{"product_id":"el-av-elrd375-u-refrigerated-air-dryer","title":"EL-AV ELRD375-U Refrigerated Compressed Air Dryer (375 CFM, 2\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD375-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e375 CFM \/ 10,620 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526529155153,"sku":"ELRD375-U","price":8650.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/SD_dryers_Small__20240326141348.614_9f83c476-86c6-41a6-8e34-1b792af966f9.png?v=1781016158"},{"product_id":"el-av-elrd480-u-refrigerated-air-dryer","title":"EL-AV ELRD480-U Refrigerated Compressed Air Dryer (480 CFM, 2 1\/2\" NPT)","description":"\u003cp\u003e\u003cstrong\u003eEL-AV ELRD Series\u003c\/strong\u003e refrigerated compressed-air dryers cool\nincoming compressed air to a stable \u003cstrong\u003e+3°C \/ 38°F pressure dew\npoint\u003c\/strong\u003e — the industry-standard target for general plant air, removing\n99% of the liquid water that causes line corrosion, rusty fittings, and\npneumatic-tool failure.\u003c\/p\u003e\n\u003cul\u003e\n \u003cli\u003e\n\u003cstrong\u003eStainless-steel brazed-plate heat exchanger\u003c\/strong\u003e — compact, high-efficiency, low pressure drop\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHermetic refrigeration compressor\u003c\/strong\u003e on rubber anti-vibration mounts\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eHot-gas bypass\u003c\/strong\u003e capacity control prevents evaporator freeze-up at light loads\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003eElectronic auto-drain\u003c\/strong\u003e with manual override standard\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e14 bar \/ 203 PSI\u003c\/strong\u003e max working pressure\u003c\/li\u003e\n \u003cli\u003e\n\u003cstrong\u003e45°C \/ 113°F\u003c\/strong\u003e max ambient temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eELRD480-U — Detailed Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 CFM \/ 13,590 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet \/ Outlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Dew Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+3°C \/ 38°F (at rated inlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Working Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 bar \/ 203 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ambient Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45°C \/ 113°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Working Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C \/ 34°F\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic auto-drain with manual override\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel brazed-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-gas bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EL-AV factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eAll CFM and l\/min ratings are for reference only.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eSizing \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eDryers are rated at standard reference conditions (35°C inlet, 100 PSI,\n38°C ambient). For hotter inlets or lower line pressures, apply the\nmanufacturer's correction factors — or call us and we'll size for your\nduty cycle. \u003cstrong\u003eAlways pair a refrigerated dryer with a coalescing\nprefilter\u003c\/strong\u003e (see our EL-AV EF Series line filters) to protect the\nheat exchanger from oil aerosols.\u003c\/p\u003e\n","brand":"EL-AV","offers":[{"title":"Default Title","offer_id":59526529220689,"sku":"ELRD480-U","price":9850.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1662\/4465\/files\/SD_dryers_Small__20240326141348.614_0527348d-9284-4c27-bcad-956a5740c94c.png?v=1781016161"}],"url":"https:\/\/a1compressorwarehouse.com\/collections\/brazed-plate-air-dryers.oembed","provider":"A1 Compressor Warehouse","version":"1.0","type":"link"}